亚洲一级电影在线观看,九九精品无码专区免费,亚洲AV无码资源在线观看 ,欧美国产高清

內存耗盡導致系統緩慢的解決方法

時間:2024-06-12 16:27:31 Linux認證 我要投稿
  • 相關推薦

內存耗盡導致系統緩慢的解決方法

  一套測試庫系統響應緩慢,通SQLPLUS登陸到數據庫中大約5-6秒才能登陸進去,正常情況下也就1秒即可登陸,簡單的一個show parameter 命令也得好幾秒才返回。下面YJBYS小編為大家整理了關于內存耗盡導致系統緩慢的解決方法,希望對你有所幫助。

  登陸到數據庫中發現ALERT文件報了大量的ORA-3136錯誤信息。

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  Tue Jan 10 11:19:17 2012

  WARNING: inbound connection timed out (ORA-3136)

  ORA-3136錯誤一般在網絡不穩定,數據庫系統資源耗盡的時候,客戶端進行連接的時候容易出現。

  topas一下發現系統的內存資源耗光了,交換空間都用掉了30%多。

  MEMORY

  Real,MB 32768

  % Comp 39.6

  % Noncomp 61.2

  % Client 61.2

  PAGING SPACE

  Size,MB 32768

  % Used 31.1

  % Free 68.8

  大部分內存都被客戶端分頁占掉了。

  數據庫的物理內存為32G,交換空間為32G如下:

  $ lsattr -El mem0

  goodsize 32768 Amount of usable physical memory in Mbytes False

  size 32768 Total amount of physical memory in Mbytes False

  $ lsps -a

  Page Space Physical Volume Volume Group Size %Used Active Auto Type

  paging00 hdisk1 rootvg 16384MB 31 yes yes lv

  hd6 hdisk0 rootvg 16384MB 31 yes yes lv

  $

  檢查了一下數據庫配置ORACLE的SGA,PGA都設置的不大

  SQL> show parameter sga

  NAME TYPE VALUE

  ------------------------------------ ---------------------- -----------

  lock_sga boolean FALSE

  pre_page_sga boolean FALSE

  sga_max_size big integer 10G

  sga_target big integer 10G

  SQL> show parameter pga

  NAME TYPE VALUE

  ------------------------------------ ---------------------- -----------

  pga_aggregate_target big integer 4G

  總共才14G,還有大約18G的空間可供操作系統利用,不應該出現內存緊張的問題。

  $ vmstat -v

  8388608 memory pages

  7961825 lruable pages

  10110 free pages

  4 memory pools

  994480 pinned pages

  80.0 maxpin percentage

  20.0 minperm percentage

  80.0 maxperm percentage

  63.9 numperm percentage

  5093543 file pages

  0.0 compressed percentage

  0 compressed pages

  63.9 numclient percentage

  80.0 maxclient percentage

  5093543 client pages

  0 remote pageouts scheduled

  32561 pending disk I/Os blocked with no pbuf

  18706130 paging space I/Os blocked with no psbuf

  2740 filesystem I/Os blocked with no fsbuf

  200 client filesystem I/Os blocked with no fsbuf

  1904898 external pager filesystem I/Os blocked with no fsbuf

  0 Virtualized Partition Memory Page Faults

  0.00 Time resolving virtualized partition memory page faults

  通過vmstat -v 發現系統的內核參數 maxperm, maxclient 都設置為80%,對于數據庫系統來說,這個設置的太高了。

  numperm percentage 都達到了63.9 了,大部分內存都被文件系統緩存占掉了。

  切換到root用戶執行如下命令:

  SXTESTDB11@/# vmo -p -o maxclient%=30 -o maxperm%=30 -o minperm%=10 -o strict_maxclient=1

  Setting minperm% to 10 in nextboot file

  Setting maxperm% to 30 in nextboot file

  Setting maxclient% to 30 in nextboot file

  Setting strict_maxclient to 1 in nextboot file

  Setting minperm% to 10

  Setting maxperm% to 30

  Setting maxclient% to 30

  Setting strict_maxclient to 1

  SXTESTDB11@/# vmo -L | grep strict

  strict_maxclient 1 1 1 0 1 boolean D

  strict_maxperm

  strict_maxperm 0 0 0 0 1 boolean D

  strict_maxclient

  一段時間后系統內存恢復正常;

  $ vmstat -v

  8388608 memory pages

  7961825 lruable pages

  2700191 free pages

  4 memory pools

  994864 pinned pages

  80.0 maxpin percentage

  10.0 minperm percentage

  30.0 maxperm percentage

  29.9 numperm percentage

  2384473 file pages

  0.0 compressed percentage

  0 compressed pages

  29.9 numclient percentage

  30.0 maxclient percentage

  2384473 client pages

  0 remote pageouts scheduled

  32561 pending disk I/Os blocked with no pbuf

  18706130 paging space I/Os blocked with no psbuf

  2740 filesystem I/Os blocked with no fsbuf

  200 client filesystem I/Os blocked with no fsbuf

  1904898 external pager filesystem I/Os blocked with no fsbuf

  0 Virtualized Partition Memory Page Faults

  0.00 Time resolving virtualized partition memory page faults

  numperm percentage 已經大大降低。

  topas系統內存情況如下:

  MEMORY

  Real,MB 32768

  % Comp 39.6

  % Noncomp 28.9

  % Client 28.9

  再次登錄數據庫,即可瞬間完成。

【內存耗盡導致系統緩慢的解決方法】相關文章:

電腦內存常見故障及解決方法05-12

手機內存卡故障及解決方法10-10

內存導致電腦花屏怎么解決10-16

JAVA垃圾收集算法與內存泄露的解決方法12-04

Linux系統死機解決方法01-22

電腦內存六大故障以及解決方法09-26

Windows系統常見的幾個故障及解決方法08-12

導致開關電源嘯叫的原因及解決方法08-25

智能會議系統常見故障及解決方法10-24

Intel傲騰內存是內存還是固態硬盤06-17

主站蜘蛛池模板: 国产成人精品无码一区二 | 成人无码视频97免费| 国产成熟妇女性视频电影| 精品久久久久久久免费影院 | 一本一本久久aa综合精品| 国产亚洲色欲色一色www| 亚洲av无码专区在线厂| 拉萨市| 国产呦精品一区二区三区下载| 全免费a级毛片免费看不卡| 99热这里只有精品2| 成人免费777777| 国产精品无码a∨麻豆| 亚洲偷自拍国综合| 国产精品aⅴ视频在线播放| 人妻.中文字幕无码| 无码毛片aaa在线| 国产美女被遭高潮免费| 国产精品18久久久久久麻辣| 无码纯肉视频在线观看| 国产乱子伦精品免费视频| 伊人网在线免费视频| 响水县| 欧美激情网址| 国产成人亚洲综合网站小说| 一本大道大臿蕉无码视频| 成人精品视频99在线观看免费| 中文字幕乱码久久午夜| 久久婷婷五月综合色国产香蕉| 久久超乳爆乳中文字幕| av片在线观看永久免费| 在线a人片免费观看| 亚洲欧美综合精品成人网| 亚洲综合日韩av无码毛片| 日韩色欲人妻无码精品av| 九九久久精品免费观看| 久久夜色精品国产噜噜亚洲sv | 亚洲欧美日韩视频高清专区| 自拍区小说区图片区亚洲| 自偷自拍三级全三级视频| 国模无码一区二区三区不卡|